Filter performance can be described in a mathematical model to promote the understanding of stacked rapid sand filters. A variable that has been suspected to affect filter efficiency is coagulant dosage. The StaRS filtration experimental apparatus was adjusted by removing the flow accumulator to prevent sand from entering the inlet system and adding a flocculator to create small flocs. The collected data will be used to create a mathematical model to examine how coagulant mass affects the filter's effluent turbidity, head loss, and breakthrough time. 

Fall 2016

Experiments with varied PACl dosages were ran to test the performance of the stacked rapid sand filter. Head loss and effluent turbidity were collected from the experiments with influent water at 5 NTU. The data from these experiments were used to create a mathematical model on the performance of the filter. The created model will then be used to write a research paper on a model for stacked rapid sand filters. The team hopes to publish this paper.

The StaRS filtration apparatus will be modeled as cluster of capillary tubes to examine the physics that allow for particle removal in the apparatus. Using the relationships between head loss, effluent turbidity, and pC*, the subteam can approximate certain properties of the flocs inside the filter column and of each individual capillary tube. The information will be used to identify an overarching relationship between influent coagulant dose and approximate filter failure time and examine the hypothesis that there are small sections of particle removal in which particles are removed. 

Section
Column
Members

Jonathan Harris

Theresa Chu

Lucinda Li

Email Team

Column
Documents

 

Challenges

Tasks

Literature Search

Symposium

Final Presentation

Final Report

Spring'16    

Fall '15

   
Spring '15  
Fall '14 

Spring '14

 

 

Fall '13

 

 

Summer '13

 

 

Spring '13

Column
 

...