Image Added

 

Consider an uniform flow of V = 10m/s passing through a Vertical Axis Wind Turbine (VAWT) as sketched above. The VAWT has a diameter of 12cm and 3 blades, each one with a chord length of 2cm. For simplification, consider that it spins with a constant angular velocity of 40 RPM*

Note

Under Construction

Simplification : No airfoil, but flat plat with 20deg angle of attack

...

Drawing, explain the simplifications (2D, etc). 

Specify diameter, number of blades, size of plates, angular velocity, incoming wind speed, 

...

Describe what happen downstream of the turbine and think on how that would affect following turbines. Array.

 * Note that this is an important simplification. Here we're considering that the turbine is already spinning independently of the flow, what is clearly not true, since the flow is responsible for spinning the turbine. However, modeling the movement of a geometry caused by the flow is extremely advanced, and require use of a method called "6DOF solver". A tutorial on that will be made in the future. For now, let's stick simpler analysis, first a steady state picture of the problem (this tutorial), and later a transient analysis (future tutorial).



Go to Step 1: Pre-Analysis & Start-Up

...