Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Migrated to Confluence 4.0
Include Page
SIMULATION: FLUENT Google AnalyticsSIMULATION:
FLUENT Google Analytics
Include Page
SIMULATION: Steady Flow Past a Cylinder - PanelSIMULATION:
Steady Flow Past a Cylinder - Panel

...

Second Order Upwind Momentum Scheme

Solution > Solution Methods > Spatial Discretization.
Set Momentum to Second Order Upwind

Convergence Criterion

Solution > Monitors > Residuals > Edit....
Set the Absolute Criteria for continuity, x-velocity and y-velocity to 1e-6. Click ok

Solution > Monitors > Create > Drag



Then check Print to Console and Plot. Next, click cylinderwall, which is located under Wall Zones. Lastly, click ok

Initial Guess

Solution > Solution Initialization > Standard Initialization.
Set Compute From to farfield1. Alternately, you can simply set X Velocity to 1 m/s. Then, click Initialize.

Iterate Until Convergence

Solution > Run Calculation.
Set the Number of Iterations to 2000. Then, click Calculate. (You may have to hit Calculate twice.) Now, have a cup of coffee. The solution should converge after approximately 1600 iterations.

...