Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

HTML
<iframe width="640" height="360" src="//www.youtube.com/embed/1mgms59QTI8" frameborder="0" allowfullscreen></iframe>

Summary of steps in the above video:

  1. Solution Methods
    1. Change Scheme to Coupled 
    2. Pressure to Standard
    3. Check Pseudo Transient and High Order term relaxation 
  2. Monitors
    1. Change the residuals of each field to 1e-6
    2. Create a surface monitor
      1. Select plot
      2. Select write
      3. Select Blade surface
  3. Solution Initialization
    1. Standard
      1. From inlet
  4. Run Calculation
    1. Set the number of iterations to 1500
    2. Initialize and Run calculation

...

Summary of steps in the above video:

...

  1. Change Scheme to Coupled 
  2. Pressure to Standard
  3. Check Pseudo Transient and High Order term relaxation 

...

  1. Change the residuals of each field to 1e-6
  2. Create a surface monitor
    1. Select plot
    2. Select write
    3. Select Blade surface

...

  1. Standard
    1. From inlet

...

 

Go to Step 6: Numerical Results

...