Include Page
SIMULATION: FLUENT Google AnalyticsSIMULATION:
FLUENT Google Analytics
Include Page
SIMULATION: Partially Premixed Combustion - PanelSIMULATION:
Partially Premixed Combustion - Panel

...

To write and save the PDF file that you just generated, go to File-Write-PDF at the menu at the top of the screen.

...

Edit the outlet boundary condition, which is a pressure outlet. Use 10% for Backflow Turbulent Intensity, and 0.13m for the Backflow Hydraulic Diameter. Clicking to the Species tab, change the Backflow Progress Variable to 1. This means that the boundary condition where the progress variable is 1.0 will only be applied in the case that there is backflow from this outlet.

Image RemovedImage Added


Go to Step 5: Numerical Solution

...