In the Outline window, select Solution Controls to open the Solution Controls window. Ensure that the Courant Number is set to 5.0.

Monitors

In the Outline window, click Monitors to open the Monitors window. In the Monitors window, select Residuals - Print,Plot and press Edit.... This will open the Residual Monitors window. We want to change the convergence criteria for our solution. Under Equation and to the right of Continuity, change the Absolute Criteria to 1e-6. Repeat for x-velocity, y-velocity, and energy, then press OK.

...

In the Outline window, select Run Calculation. Change the Number of Iterations to 100. Double click Calculate to run the calculation. It should only take about a minute to solve. After the calculation is complete, save the project.

Go to Step 6 - Results

Go to all FLUENT Learning Modules