Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

For convenience, you can import quantities from FLUENT into CFD-Post. From FLUENT, click on File > Data File Quantities:

Image Modified|^data file.png]

In Data File Quantities dialogue, select the desired quantities and click on OK.

Image RemovedImage Added

Info
titleNote

Students in MAE 6510 will need to select the Nusselt number in addition to the skin friction coefficient for your HW assignment. In ANSYS user manual, reference values are used to define the skin friction coefficient and the Nusselt number. Hence, you will need to specify the appropriate reference density, velocity, length, and temperature in FLUENT before you solve the model.

Image Added

Double click on Results from the Workbench Window to launch CFD-Post.

...

It is of interest to compare the numerical skin friction coefficient profile to the skin friction coefficient profile obtained from the Blasius solutionWe solution. We will compare the FLUENT result to the Blasius solution. Download the Blasius solution here. The comparison is shown below:

...