Again 50 for the sample size
Click Apply. You will see wall created under User Locations and Plots.
...
Now click on Data Series tab to specify the location of the chart data. Change the name of the first data series from Series 1 to FLUENT. Under Data Source, specify Wall as Location.
As before, we would also like to compare our simulation result with experimental data. Experimental data can be downloaded here. Now, click a new data series . Name it Experiment. Under Data Source, select File and browse for the downloaded experimental data.
Again in this case, the x-axis is the x-position along the pipe and the y-axis denotes temperature.
The FLUENT result is shown in the graphics window.
...
Info | ||
---|---|---|
| ||
You need to repeat the FLUENT simulation with inputs from YOUR MEASUREMENTS in the lab. A sample comparison is shown below. You can export the data by clicking on the Export button in "Details of centerline temperature" |
Pressure Plot
Now let's us look at the pressure variation at the centerline. We can use the center-line we created earlier.
...
The FLUENT result is shown in the Graphics window.
Info | ||
---|---|---|
| ||
You need to repeat the FLUENT simulation with inputs from YOUR MEASUREMENTS in the lab. A sample comparison is shown below. You can export the data by clicking on the Export button in "Details of centerline temperature" |
Axial Velocity Profile before and after Heated Section
...