Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Include Page

...

ANSYS Google Analytics

...

ANSYS Google Analytics

...

Include Page
High Resolution FE Model of Bone - Panel
High Resolution FE Model of Bone - Panel

...

Pre-analysis & Start-Up

...

Pre-analysis

The equivalent stiffness of the model can be determined:

Image Added

where
R is the reaction force
delta is the deflection
L is the length of the model

We will find the reaction force and the support and use the above relation to verify the simulation.

...

Start-Up

Before you proceed, you need to download the Abaqus input file.

download the Abaqus file here

The following flow chart illustrates the steps to carry out ANSYS simulation starting from Micro CT Scan.

Image Added

Open ANSYS Workbench:Image Removed

Image Added

We will import the Abaqus input file into External Model and convert it into a Geometry Setup that ANSYS can simulate.

Expand Component Systems in the Toolbox. Locate Finite ElementModeler External Model and drag it into Project Schematic:

Image RemovedImage Added click here for full view

Right click on Setup > Edit > Location >Browse, and locate the Abaqus input file.

Image Added

Once the Abaqus file is imported, make sure that the Unit System selected are in mm. Click on the Data Source cell (Cell A2), then check the unit system is as shown below:

Image Added

Image Added

Click on the Project Tab to return to Project Schematic. You should see an update symbol Image Added next to Setup. This means the input file has been loaded and External Model is ready to generate a model.

Go to Step 2 - : Geometry

Go to all ANSYS Learning Modules