Double click on air and change Density to 1.0 kg/m^3 and Viscosity to 2e-5 kg/(m*s). These are the values in the Problem Specification. We'll take both as constant.

...

Choose inlet and click on Edit.... Change the Velocity Specification Method to Magnitude, Normal to Boundary. Enter 1 m/sfor Velocity Magnitude. This indicates that the fluid is coming in normal to the inlet at the rate of 1 meter per second. Select Intensity and Hydraulic Diameter next to the Turbulence Specification Method. Then enter 1 1% for Turbulence Intensity and 0.22m for Hydraulic Diameter. Click OK to set the velocityboundary conditions for the inlet.


 
The (absolute) pressure at the outlet is 1 atm. Since the operating pressure is set to 1 atm, the outlet gauge pressure = outlet absolute pressure - operating pressure = 0. Choose outlet under Zone. The Type of this boundary is pressure-outlet. Click on Edit. The default value of the Gauge Pressure is 0. Click Cancel to leave the defaults in place.

...