In the Solution sub menu select Strain > Normal. Now, we need to specify that we want the strain to be measured at the stain gauge in the y direction. To accomplish this, go to Scoping Method > Path, the select Path > Strain Gauge in the details window. To change the direction of the strain, select Orientation > Y Axis. The rest of the default options should suffice for our simulation.

When

all of the settings are finished, press We are ready to solve the simulation. Press

Continue to Step 6: Results