Then, head loss through both the tubing and orifice plates are calculated given user input for width and number of orifice plates along with the length of the desired tubing. This total head loss through the system is the summation of the head loss through the orifices plates and the head loss through the wider, encompassing tubing.

'''**Head Loss Through Orifice Plates:'''**
'''

**Head Loss Through Tubing:'''**

Using this information, the necessary flow of alum from the doser based on dimensions given above is determined. Using a stock dose concentration of 1.5 mg/L, the necessary stock concentration is found as well.

...