Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

FLUENT reports a residual for each governing equation being solved. The residual is a measure of how well the current solution satisfies the discrete form of each governing equation. We'll iterate the solution until the residual for each equation falls below 1e-6. In order to specify the residual criteria (Click) Monitors > Residuals > Edit..., as shown in the image below.


newwindow
Click Here for Higher Resolution
Click Here for Higher Resolution
https://confluence.cornell.edu/download/attachments/118771076/EditResid_Full.png


Next, change the residual under Convergence Criterion for continuity, x-velocity,and y-velocity, all to 1e-6, as can be seen below.


newwindow
Click Here for Higher Resolution
Click Here for Higher Resolution
https://confluence.cornell.edu/download/attachments/118771076/ResidMon_Full.png


Lastly, click OK to close the Residual Monitors menu.

Set Initial Guess

Here, the flow field will be initialized to the values at the inlet. In order to carry out the initialization click on Solution Initialization then click on Compute from and select inlet as shown below.

Image Added

newwindow
Click Here for Higher Resolution
Click Here for Higher Resolution
https://confluence.cornell.edu/download/attachments/118771076/CompFromInlet_Full.png


Then, click the Initialize button, Image Added. This completes the initialization process.







Solution > Solution Initialization

...