Under Details of "Edge Sizing", enter 60 for Number of Divisions. Under Bias select:

"---- -- - -" and when asked for the bias factor please enter 20.


Similarly, specify element size of 0.015m for Edge Sizing 2

Click Update to generate the new mesh. Under Statistics, we should have mesh with 24,420 elements.

Close the ANSYS Mesher and go back to Workbench windows. Under Forced Convection Refined Mesh, right click on Fluid Flow (FLUENT) and click Update. Wait for a few minutes for FLUENT to obtain a solution.

...