Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

A standard outlet pressure was set for the Double Baffle Straight Edge geometry for validation. Also a Mesh Sensitivity analysis was performed. The Mesh was refined from 3663 3,663 cells to 14652 14,652 cells to 58608 58,608 cells. Results are plotted for a straight horizontal line at the middle of each baffle. These results are for Velocity Magnitude and Pressure Coefficient. Furthermore a contour of the strain rate was created to show shear velocity gradients around the 180 degree bend.

...