Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Select inletunder Compute Fromto tell FLUENT to use values at the pipe inlet for the reference values. Check that the reference value for density is 1 kg/m3, velocity is 1 m/s, and coefficient of viscosity is 2e-5 kg/m-s as given in the Problem Specification.These reference values will be used to non-dimensionalize the distance of the cell center from the wall to obtain the corresponding y+ values. Click OK.


 
Let's plot y+ values for wall-adjacent cells to check how it compares with the recommendation mentioned above.

...

Click on Curves... in the Solution XY Plot window. Select the solid line option under Pattern as shown below. Change Weight to 2. Select the blank option under Symbol. Click Apply and Close.


 
Turn on grid lines: In the Solution XY Plot window, click on Axes.... Turn on the grid by checking the boxes Major Rules and Minor Rules under Options. Leave Auto Range checked. Click Apply. Select Y under Axis and repeat. Click Apply and Close.

Uncheck Write to File. Click Plot.


Click here to see a higher resolution image.

...

Uncheck Write to File. Click Plot.


Click here to see a higher resolution image.

...

Uncheck Write to File. Click Plot.


Click here to see a higher resolution image. 

...