Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Migrated to Confluence 4.0

...

  • Raw water flows from the distribution tank, into a holding reservoir. The holding reservoir is necessary as it allows air trapped in the water line to escape before sending it through the filter. Air cannot be allowed into the filter as it will alter the results of filter performance.
  • The water is then pumped into the top of the filtration apparatus, and down through the filters.
  • The effluent water line continues to the turbidimeter where the effluent turbidity is measured.
    Image Modified

Figure 1: Schematic of foam sheet experiment

...