INTRODUCTION


The former ANC group experimented on different designs for a lime feeder, including a column model, a conical vessel, a funnel-column and an inverted traffic cone model.

The Column model succeeded in keeping the lime suspended for a few hours but the water began to flow in a preferential path after the lime settled on the bottom. For the conical column, the mixing at the bottom of the vessel proved to be insufficient in keeping all the lime in a suspended state. On the other hand, the funnel-column apparatus worked well for 20 hours but only because it was unclogged periodically, which would not possible in a real-time set up. As a result, the inverted cone model that supplied saturated limewater at a pH between 11 and 12 for about 18 hours without having to be unclogged and without the above difficulties was selected as the best alternative among them.
The most effective design was the inverted cone because it . However, the main problem with it is that inverted cones are extremely difficult and expensive to construct, install and maintain. So the task of the ANC team is to search for a simpler solution for the lime feeder design.

...