Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Preliminary experiments were conducted to determine the appropriate time interval for the flow and increment states. These experiments consisted of running the system for an exorbitant length of time to identify the timeframe necessary to reach constant effluent turbidity. Ultimately, we decided to form the floc blanket for three hours; run each flow rate for six hours; stop effluent flow for ten seconds between flow rates; and allow about twenty minutes for the floc blanket to grow from its low to high depths. The floc blanket was reformed each time a new diameter was tested.

Results

Image Modified
Table 1. Results

...

The wider tube settlers, as expected, provided slightly more sensitive data. That is, the effluent turbidity was measurably impacted by changes in flow rate, floc blanket height, and tube diameter. The table above and the graph below illustrate the average effluent turbidity for the three diameters described in the methods section above.

Image Modified
Graph 1. Effluent Turbidity vs. Critical velocity

...