The diameters of the tubes were chosen to explore a range of spacings based on the current plate spacings used in plants of two inches. The flow rates were chosen to explore a range of capture velocities from 5-20 m/day.

Image Modified
Table 1. Critical velocity table.

As described on our apparatus design page, this experiment used the process controller program to automate the system. The main process controller states for the experiment were floc blanket formation, two flow states for high and low floc blanket heights, a floc blanket equilibrium state, and two states devoted to incrementing the flow rates. Several other states, such as drain, were used for system maintenance.

...