Before we can make any conclusion about the accuracy of our result, we should always make validation check. The most common validation step is grid convergence check.
A finer mesh with four times the original mesh density was created. The lift coefficient was found to be 0.649.
| Original Mesh | Fine Mesh | %Dif |
---|---|---|---|
CL | 0.647 | 0.649 | 0.3% |
Comparisons
With our simulation data, we can now compare the Fluent with experimental data. The summary of result is shown in the table.
...