Change Momentum to Second Order Upwind.


Click OK.

Set Initial Guess

...

In the Solution Initialization menu that comes up, choose inlet under Compute From. The Axial Velocity for all cells will be set to 1 m/s, the Radial Velocity to 0 m/s and the Gauge Pressure to 0 Pa. These values have been taken from the inlet boundary condition.

Click Init. This completes the initialization. Close the window.

...

Also, under Options, select Plot. This will plot the residuals in the graphics window as they are calculated.


Click OK.

Monitor also the drag coefficient on the cylinder.

...