You can also look at specific parts of the grid by choosing the boundaries you wish to view under Surfaces (click to select and click again to deselect a specific boundary). Click Display again when you have selected your boundaries. For example, the wall, outlet, and centerline boundaries have been selected in the following view:
These options will display the graph:
(Click picture for larger image)
For convenience, the button next to Surfaces selects all of the boundaries while the deselects all of the boundaries at once.
Close the Grid Display Window when you are done.
Define Solver Properties
Main Menu > Define > Models > Solver
Choose Axisymmetric under Space. We'll use the defaults of pressure based ("segregated", in older versions) solver, implicit formulation, steady flow and absolute velocity formulation. Click OK.
Use the default setting. Click Cancel.
Main Menu > Define > Models > Viscous
...
Change Density to 1.0
and Viscosity to 2e-3
0.1
. These are the values that we specified under Problem Specification. We'll take both as constant.
Click Change/Create. Close the window.
...
For all flows, FLUENT uses gauge pressure internally. Any time an absolute pressure is needed, it is generated by adding the operating pressure to the gauge pressure. We'll use the default value of 1 atm (101,325 Pa) as the Operating Pressure.
Click Cancel to leave the default in place.
Define Boundary Conditions
...