All data was corrected in MathCAD so that float heights and lever arm positions were converted into chem doser heights at each position out from the pivot. The chem doser height is actually the change in height downward from the zero level, which corresponds to the driving head on the system being applied by the moving lever arm. This was then plotted on a graph to show the relationship between doser height and outflow measured, which can be seen below.

Image RemovedImage Added

The data fall along a nearly-linear path with a spread of about 0.2 mL/sec that appears to fall off around 1.1 mL/sec outflow. There is relatively little data collected at the heigher flowrates, though, so this conclusion is not very concrete.

To make sure that the system was tested in the laminar flow range, the following Reynold's Number analysis was performed. As can be seen in the graph, the system should not have approached the turbulent transition during testing with head losses of 0-20 cm.

Image Added

The MathCAD program (ACDFall08LeverTCDFall08LeverT) used to analyze this data can be found attached here.