Comment: Migration of unmigrated content due to installation of a new plugin

...

Our port code (floctankbaffleportscript) was made to draw ports on alternating sides of the lower baffles so that water does not drain linearly through the tank (thus not getting mixed properly.) In order to subtract these quickly, the baffles were unioned in addition to the ports themselves.

We restructured the AutoCAD scripts wiki page to be more descriptive. All of the AutoCAD scripts for the flocculator should now be up to date, including pictures.

Jeff, Julie, and I worked on the code for the horizontal flocculator. Generic variables for lengths and widths were used to calculate dimensions, allowing us to reuse the same code for both the horizontal and vertical cases. Also, most of the existing position calculations were converted into matrices of the same size so that the code would be loaded to handle both vertical and horizontal calculations. The position calculations for the baffles change (using an if statement) depending on whether the number of channels is even or odd. A code strictly for the horizontal case currently draws an accurate floc tank, but more work must be done to incorporate the decision variable between the horizontal and vertical flocculators so that a single file can be used to calculate positions and dimensions for either case.