Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Migrated to Confluence 4.0

...

Approximately 120 hours later (5 days later), the stock solution was refilled with the same concentration (41.5 g/L). However, the blender had been repaired at this time and was used to prepare the slurry, instead of the mixer. At the same point in time (5 days from the beginning of the experiment) the flow rate for the peristaltic pump flowing to the 5 cm tube settler was increased from 40 mL/min to 50 mL/min in an attempt to raise the pH.    The team suspects that when the flow rate in the 5 cm tube settler apparatus is too low, the lime particles settle and create preferential flow paths which keeps the lime from interacting with the water.

Below in figures 1, 2 and 3 Below is the preliminary data from the experiment:                                           
Image Removed
                                                                 .  The 2.5 cm plate settler was relatively stable, achieving a pH of over 12 for well over a week!  The 5 cm plate settler, however, never reached a pH of 12 but rather oscillated around a value of approximately 11.5.  As time went on, the amplitude of the data's wave increased and the pH started regularly dipping below 10.                                          
Image Added
                                                                                                                                           Figure 1 - Experiment 9: data from
                                                             The above graph is hours 0 to 40 of an experiment pulsing in 41.5 g/L of lime slurry at 380 mL/min for 1 minute  every six hours.

 
                                                                                                                                                                                                                                                            Figure 2 - Experiment 9: data from
                                                               The above graph is hours 40 to 80
  Image Removed
                                                                                                               of an experiment pulsing in 41.5 g/L of lime slurry at 380 mL/min for 1 minute  every six hours.   Image Added
                                                                                                                                             Figure 3 - Experiment 9 : data from hours 80 to 120
                                                          The above graph is hours 80 to 120 of an experiment pulsing in 41.5 g/L of lime slurry at 380 mL/min for 1 minute  every six hours.

Experiment 9 ran for nearly 10 days before the team shut it down.  The performance of the 2.5 cm tube settler remained pretty consistent, with the pH remaining right around 12.  The 5 cm tube settler continued its wave-like motion, as seen in Figure 4.
Image Added
 

                                                                                                                                    Figure 4 - Experiment 9, Day 9

This graph is zoomed in to display that the smaller apparatus does experience slight peaks with each lime pulse, and to not that the larger apparatus dips below a pH of 10 as the experiment continued.