Basics of Laboratory Research and Experimental Design

Experimental Design

An important part of your experiment is to envision how it will be accomplished. Before you even begin setting up an experiment, you should understand what you want to measure and why you are measuring it. Include details on the wiki and update your Research Plan Detailed Task List.

You should sketch out how you will set up the experiment. If you have an existing experiment, think about what if anything needs to be modified.

After you have an idea of what sort of experiment you will run and how you will set it up, you should utilize Process Controller to automate the experiment. Details of how to use Process Controller ProCoDA Software can be found on the wiki.

Equipment in the Laboratory

Tubing and Tubing Connections

There exist two types of tubing that we utilize in conducting experiments: flexible soft peristaltic (easily bendable) and inflexible hard tubing.

Peristaltic pump tubing is rubber and has sizes a special formulation (we use a formulation called PharMed) designed to be very flexible. The manufacturer labels the tubing arbitrarily with size designations of 13, 14, 16, 17, and 18. Rubber Peristaltic pump tubing can be connected to other types of tubing using a barbed fitting. Only put rubber peristaltic tubing on the barb. Note: If you put inflexible tubing on a barbed connector, you may never get it off again.

Simple rules to remember:

  • Rubber soft tubing for peristaltic pumps with a barbed connector.
  • Inflexible hard tubing goes with a push-to-connect connector.
  • Other flexible tubing (tygon or PVC formulation) is useful in creating coils and bends for flocculators and can be put into a push-to-connect connector.

Making Tubing Connections

When you make a connection utilizing a push-to-connect connector, ensure that you push the tube as fully in as you can gois fully engaged in the connector. The tube needs to slide inside of an o'ring seal in the connector. You should feel a pop, when the tube is fully in and is caught by the push-to-connect connectorslides inside the o'ring.

With rubber peristaltic pump tubing, ensure that the tubing tightly fits over the barbed part.

Exercise in Experimental Design and Set-Up

Here is a sample exercise that should help to set up an experiment in lab. In a group or individually sketch out an experimental schematic of a mixing process to blend to chemicals.

...