Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Migration of unmigrated content due to installation of a new plugin
Wiki Markup
{composition-setup}
cloak.toggle.exclusive=false
{composition-setup}

h2. 

Wiki Markup
{toggle-cloak:id=Abstract}
Abstract

Wiki Markup
 Abstract

{cloak:id=Abstract}

The

...

Lab

...

Flocculator

...

research

...

team

...

has

...

an

...

important

...

focus

...

on

...

investigating

...

the

...

relationship

...

between

...

fluid

...

shear

...

(G)

...

and

...

its

...

effect

...

on

...

overall

...

flocculator

...

mixing

...

(Gtheta).

...

Floc

...

formation

...

and

...

breakup

...

rates

...

depend

...

greatly

...

on

...

the

...

Gtheta

...

parameter,

...

which

...

is

...

intrinsically

...

related

...

to

...

the

...

fluid

...

shear

...

present

...

inside

...

a

...

reactor.

...

The

...

semester

...

research

...

goals

...

of

...

the

...

Lab

...

Flocculator

...

research

...

team

...

was

...

to

...

measure

...

the

...

relationship

...

between

...

G

...

and

...

Gtheta

...

by

...

performing

...

experiments

...

using

...

a

...

coiled-tube

...

flocculator

...

experimental

...

apparatus.

...

The

...

team

...

decided

...

to

...

first

...

perform

...

experiments

...

to

...

determine

...

the

...

appropriate

...

alum

...

dose

...

to

...

achieve

...

optimal

...

floc

...

formation

...

for

...

the

...

experimental

...

apparatus.

...

Experimental

...

data

...

showed

...

that

...

a

...

25

...

mg/L

...

concentration

...

of

...

alum

...

produced

...

the

...

best

...

results

...

for

...

a

...

range

...

of

...

influent

...

turbidity

...

between

...

50-150

...

NTU

...

and

...

a

...

humic

...

acid

...

concentration

...

of

...

35

...

mg/L

...

with

...

minimal

...

marginal

...

improvements

...

thereafter;

...

thus,

...

subsequent

...

experiments

...

were

...

conducted

...

with

...

a

...

constant

...

25

...

mg/L

...

alum

...

dose.

...

Throughout

...

the

...

semester,

...

the

...

team

...

was

...

faced

...

with

...

numerous

...

obstacles

...

originating

...

from

...

the

...

physical

...

apparatus

...

and

...

the

...

various

...

software

...

used

...

by

...

the

...

team.

...

Sedimentation

...

of

...

clay

...

inside

...

feed

...

tubing

...

and

...

the

...

flocculator

...

inhibited

...

various

...

experimental

...

controls

...

including

...

influent

...

turbidity,

...

flow

...

rates,

...

and

...

also

...

data

...

collection.

...

Measures

...

were

...

taken

...

to

...

overcome

...

this

...

issue,

...

but

...

sedimentation

...

should

...

ideally

...

only

...

occur

...

in

...

the

...

settling

...

column

...

during

...

the

...

appropriate

...

operational

...

state.

...

The

...

flocculator

...

team

...

has

...

overcome

...

a

...

large

...

learning

...

curve

...

of

...

needing

...

to

...

understand

...

the

...

experimental

...

setup,

...

Process

...

Controller,

...

and

...

the

...

MathCAD

...

data

...

processor

...

tools.

...

Much

...

data

...

was

...

collected

...

of

...

different

...

combinations

...

of

...

important

...

variables

...

such

...

as

...

flow

...

rate,

...

influent

...

turbidity,

...

and

...

flocculator

...

length.

...

Currently,

...

only

...

a

...

qualitative

...

analysis

...

of

...

the

...

data

...

has

...

been

...

performed

...

and

...

the

...

team

...

is

...

satisfied

...

with

...

the

...

data

...

set

...

obtained.

...

During

...

coming

...

semester,

...

the

...

team

...

will

...

focus

...

on

...

developing

...

an

...

analytical

...

model

...

to

...

better

...

analyze

...

the

...

data

...

as

...

well

...

as

...

to

...

present

...

it

...

in

...

intelligible

...

figures

...

and

...

charts

...

in

...

preparation

...

for

...

publication.

Wiki Markup

{cloak}

h2. 

Wiki Markup
{toggle-cloak:id=Introduction}
Introduction

Wiki Markup
 Introduction

{cloak:id=Introduction}

The

...

goal

...

of

...

finding

...

a

...

relationship

...

between

...

G

...

and

...

G¿

...

is

...

not

...

simple;

...

it

...

requires

...

many

...

experiments

...

and

...

a

...

lot

...

of

...

data

...

analyses.

...

It

...

is

...

an

...

important

...

relationship

...

to

...

determine

...

because

...

it

...

is

...

hypothesized

...

that

...

with

...

the

...

increase

...

in

...

the

...

length

...

of

...

the

...

flocculator,

...

the

...

max

...

G

...

required

...

to

...

continue

...

to

...

build

...

flocs

...

decreases.

...

Keeping

...

the

...

flocculator

...

at

...

a

...

constant

...

G

...

throughout

...

the

...

tube

...

may

...

be

...

compromising

...

the

...

floc

...

strength

...

and

...

growth,

...

as

...

the

...

flocs

...

will

...

build

...

throughout

...

the

...

flocculator

...

and

...

then

...

break

...

up

...

from

...

the

...

shear

...

forces

...

at

...

the

...

end

...

of

...

the

...

flocculator.

...

Floc

...

growth

...

depends

...

on

...

G,

...

alum

...

concentration,

...

particle

...

concentration,

...

and

...

the

...

residence

...

time

...

of

...

the

...

flocculator.

...

As

...

particles

...

floc

...

together

...

and

...

the

...

floc

...

become

...

larger,

...

the

...

strength

...

of

...

the

...

floc

...

becomes

...

weaker

...

with

...

volume,

...

so

...

it

...

is

...

more

...

prone

...

to

...

break

...

up

...

at

...

the

...

end

...

of

...

the

...

flocculator.

...

By

...

reducing

...

the

...

shear

...

forces

...

on

...

the

...

flocs

...

at

...

the

...

end

...

of

...

the

...

flocculator,

...

the

...

flocs

...

will

...

remain

...

intact,

...

keeping

...

the

...

effluent

...

turbidity

...

low.

...


The

...

effectiveness

...

of

...

alum

...

dosage,

...

flocculator

...

residence

...

time,

...

and

...

G

...

is

...

measured

...

by

...

the

...

size

...

of

...

flocs

...

after

...

flocculation.

...

Since

...

the

...

equipment

...

needed

...

to

...

observe

...

and

...

measure

...

the

...

sizes

...

of

...

flocs

...

formed

...

after

...

each

...

experiment

...

does

...

not

...

exist,

...

the

...

rate

...

at

...

which

...

flocs

...

settle

...

under

...

quiescent

...

conditions

...

must

...

be

...

analyzed

...

along

...

with

...

the

...

final

...

settled

...

turbidity.

...

Since

...

the

...

experiments

...

were

...

run

...

under

...

identical

...

conditions,

...

the

...

mechanisms

...

creating

...

the

...

flocs

...

are

...

identical

...

from

...

run

...

to

...

run;

...

therefore,

...

the

...

composition

...

of

...

the

...

flocs

...

(their

...

shape

...

and

...

density)

...

should

...

be

...

relatively

...

uniform.

...

This

...

fact

...

allows

...

us

...

to

...

directly

...

relate

...

the

...

settling

...

rate

...

of

...

the

...

flocs

...

to

...

the

...

size

...

of

...

the

...

flocs,

...

while

...

neglecting

...

factors

...

such

...

as

...

electrostatic

...

interactions

...

and

...

porosity

...

(which

...

would

...

affect

...

drag

...

coefficients

...

and

...

densities).

...

This

...

principle

...

is

...

the

...

basis

...

of

...

the

...

laboratory

...

flocculator

...

research.

Wiki Markup

{cloak}

h2. 

Wiki Markup
{toggle-cloak:id=Methods}
Methods

Wiki Markup
 Methods

{cloak:id=Methods}

The

...

flocculator

...

setup

...

was

...

used

...

to

...

run

...

the

...

set

...

of

...

experiments.

...

G

...

was

...

incremented

...

from

...

40

...

sec-1

...

to

...

100

...

sec-1

...

by

...

an

...

interval

...

of

...

5

...

sec-1

...

at

...

each

...

turbidity

...

of

...

50,

...

75,

...

100,

...

and

...

125

...

NTU.

...

Using

...

this

...

set-up,

...

our

...

entire

...

experiment

...

was

...

automated

...

by

...

Process

...

Controller

...

and

...

ran

...

continuously

...

for

...

up

...

to

...

two

...

days

...

per

...

entire

...

run.

...

This

...

experiment

...

was

...

run

...

at

...

three

...

different

...

flocculator

...

tube

...

lengths

...

of

...

10

...

feet,

...

25

...

feet,

...

and

...

100

...

feet.

...

All

...

three

...

various

...

flocculator

...

tube

...

lengths

...

stayed

...

wrapped

...

around

...

the

...

hollow

...

plastic

...

structure

...

in

...

order

...

to

...

keep

...

the

...

transition

...

between

...

experiments

...

easy.

Wiki Markup

{cloak}

h2. {toggle-cloak:

Wiki Markup
{toggle-cloak:id=Results}
Results

Wiki Markup
 Results

{cloak:id=Results}

The

...

team's

...

goal

...

was

...

to

...

investigate

...

the

...

relationship

...

between

...

the

...

average

...

shear

...

in

...

the

...

flocculator

...

to

...

the

...

effectiveness

...

of

...

flocculation.

...

Flocculation

...

effectiveness

...

can

...

be

...

qualified

...

by

...

observing

...

the

...

settling

...

rate

...

of

...

the

...

flocs

...

during

...

quiescent

...

clarification

...

and

...

also

...

the

...

final

...

turbidity

...

after

...

a

...

period

...

of

...

time

...

corresponding

...

to

...

the

...

settling

...

velocity

...

and

...

volume

...

of

...

the

...

settling

...

column.

...

In

...

conventional

...

water

...

treatment

...

design,

...

sedimentation

...

tanks

...

are

...

designed

...

to

...

facilitate

...

the

...

settling

...

of

...

flocs

...

by

...

designing

...

to

...

the

...

critical

...

settling

...

velocity.

...

In

...

the

...

experiments

...

performed

...

this

...

semester,

...

a

...

constant

...

600

...

second

...

settling

...

time

...

was

...

set

...

for

...

all

...

runs

...

because

...

it

...

was

...

observed

...

that

...

it

...

was

...

a

...

long

...

enough

...

period

...

to

...

observe

...

final

...

settling

...

turbidities.

...

This

...

parameter

...

should

...

be

...

adjusted

...

according

...

to

...

the

...

flow

...

rate

...

and

...

the

...

initial

...

influent

...

turbidity.

...

The

...

critical

...

settling

...

velocity

...

can

...

be

...

modeled

...

with

...

first

...

principles:

...

Include Page
Newton's 2nd Law
Newton's 2nd Law

Where Fg is a force of gravity, Fb is the buoyancy force, and Fd is the force due to fluid drag. After a brief period, the particle velocity will reach steady state (dV/dt = 0) and the critical settling velocity can be given as:

Include Page
Critical Settling Velocity
Critical Settling Velocity
Include Page
Critical Settling Velocity - Simplified
Critical Settling Velocity - Simplified

There are, however, shortcomings to the derivation of this equation: For instance, the assumption that all particles are of spherical shape and therefore are affected by drag in the same manner as a sphere is far from reality. Particles are likely to have an average size distribution with a non-zero variance that are affected by mixing. Also, the assumption that all flocs will have the same density is also not very accurate. Finding a governing equation which explicitly defines the relationships between certain parameters to the settling curve would not only help us quantify the relationship between flocculation effectiveness, but it may also give us insights about how parameters (such as density, size, and shape) effect settling.
Image Added
Figure 1: Effluent Settling for various G values at Influent Turbidity of 50 NTU and Flocculator Length of 50 feet.
Image Added
Figure 2: Effluent Turbidity during Settle State - Influent turbidity of 50 NTU, flocculator length of 50 ft, 600 sec settle time
Image Added
Figure 3: Effluent Turbidity during Settle State - Influent turbidity of 50 NTU, flocculator length of 50 ft, 600 sec
Image Added
Figure 4: Effluent Turbidity during Settle State - 50-125 NTU, 25 feet
Image Added
Figure 5: Effluent Turbidity during Settle State - 50-125 NTU, 25 ft
Image Added
Figure 6: Effluent Turbidity during Settle State at 50 NTU, 10 feet
Image Added
Figure 7: Effluent Turbidity during Settle State at 50 NTU, 10 feet
Image Added
Figure 8: G¿ vs. flowrate - 50 NTU, 10 ft
Image Added
Figure 9: Effluent Turbidity in Settle State - 50-125 NTU, 10 ft
Image Added
Figure 10: Effluent Turbidity during Settle State - 25-125 NTU, 10 ft
Image Added
Figure 11: G¿ vs flow-rate for various flocculator lengths

After the first several runs at 50 NTU, it was obvious that not enough time was given to allow adequate sedimentation. Figure 1 shows the settling curve of the first several runs. One can see that if more time was given to settling, the curves should have reached lower turbidities. The settling time was then extended to 10 minutes to give plenty of time for particles to settle out and for the settling column to reach an asymptotic steady-state minimum.

Figure 2 shows the settling curve for an experiment with the same parameters, but with a 10 minute settling state instead of a 5 minute one. The curves reach a point where the downward slope of the settling curve becomes nearly flat along the time axis. If given enough time, the colloids will all come out of solution; since they are not soluble, gravity will eventually pull them out of suspension. After 600 seconds, all of the data sets show that most of the colloids have settled out and a plateau in the setting curve is reached.

Figure 3 is a different viewing perspective of the same experiment plotted in Figure 2. Figure 3 exhibits two of the biggest challenges the team faced when analyzing the data. The most troublesome part of the results is that while the influent turbidity for each of the 12 flow rate iterations was set at the same value, the initial effluent turbidities measured at the start of each settle state were different. Since the initial effluent turbidities are different, it is difficult to compare the results of the different flow rate runs. Figure 3 shows that the final settled turbidity reached a value roughly around 5 NTU for all of the runs except for three outliers (which will be discussed later). It appears from this experiment that flow rate does not affect the final effluent turbidity, but that the initial effluent turbidity is affected by flow rate. The data seems to indicate that some of the clay that was introduced into the influent stream does not make it out of the system in the effluent stream. Sedimentation is an unavoidable issue in large scale flocculators where local velocities can reach very low values; but in the tube flocculator, sedimentation inside the tubes can introduce unwanted obstacles that can change the behavior of the flow. However, while observing the experiment during operation, it was not clear where the sedimentation was occurring because there was not a significant amount of flocs settling out in the clear tubes that make up the flocculator. Even at the lowest flow rate (1.45 mL/sec), only very little sedimentation was observed inside the flocculator; therefore, the sedimentation must have been occurring in the tube connecting the clay stock to the influent stream.

A simple test of this theory was performed to determine if an adjustment was needed to prevent sedimentation in that connection tube. The system was set to pump a 50 NTU solution into the flocculator. After reaching a steady state influent NTU, the influent tube was rigorously perturbed to dislodge any clay that may have settled in the lines. As expected, the perturbation dislodged some amount of clay into the stream and the observed influent turbidity spiked significantly and slowly returned to roughly the previous steady state turbidity level. As a first attempt to solve this problem, the original rubber tubing used to connect the clay stock to the influent stream was shortened to about 25 cm---leaving only a couple cm of free tubing on each side of the peristaltic pump-head. Two new test runs were performed at multiple turbidities with a 25 ft and a 10 ft flocculator tube.

The other challenge was the presence of data discontinuities, which periodically produced settling curves that did not match the pattern of the other settling curves. Figure 9 shows that the data from flow rates of 2.2, 2.35, and 2.95 mL/sec are inexplicable higher than what one would expect them to be given what the trend of the rest of the curves. These discrepancies have consistently appeared to be a translation of a set of data (usually the set corresponding to a particular flow rate) to a higher overall turbidity. This was originally thought to have been an error introduced by the MathCAD data processing program when it extracted the information out of the raw-datalog, but after having manually extracted and plotted the data in excel, it was clear that the Data Processor code was working properly and that the supposed discrepancies were representative of how the raw data was collected.

Figure 4 and Figure 5 both show a three dimensional plot of an experiment run with a 25 ft flocculator and which also included the adjustments made on the truncated clay inlet tube. The experimental data display very nice settling patterns that could be described at first order decay. Unfortunately, the issue of clay settling inside the flocculator is still an issue. The initial effluent turbidities among the various flow rates are still not equal. While influent turbidities all reach an equal steady state turbidity value, it seems that while floc sedimentation inside the flocculator may not seem significant to the observer, the amount of settling accrued throughout the length of the flocculator adds up and may have become rather significant. Additionally, the effluent turbidity never reaches below 10 NTU---a less than optimal result. However, unlike the results from the experiments corresponding to Figure 8 and Figure 3, the final settling turbidities do seem to be effected by flow rate. Figure 5 shows that the settling turbidity gradually increases with increasing flow rate. Initially, this observation supports the idea that as shear intensity increases in the flocculator, flocs brake-up occurs and counteracts the effectiveness of the increased amount of mixing. However, a mathematical model should be developed to better quantify this assumption. Currently, all of the conclusions this team is making are based on educated evaluations of the graphical results from the various experimental runs.

Figure 6 and Figure 7 are plots of an experimental run performed at an influent of 50 NTU with a 10 flocculator prior to the rubber tube adjustment. Notice how both the initial effluent turbidities and the final settling turbidities increase with increasing flow rate (see Figure 7). Notice also that there is very little additional settling after the first 100 seconds of settling---the settling curve remains flat relative to the decline observed in the initial 100 seconds of the state. After the adjustment of the tube, an identical experiment was performed on the 10 ft flocculator and those results are displayed in Figure 9 and Figure 10. While it is difficult to determine which of the points or lines correspond to which turbidity run, it is clear that the settling curves show the same trend as the previous experiment. With a flocculator of only 10 ft, the flocs formed are either not large enough to settle out or an inadequate amount of flocs were formed. One way of gaining more insight on the quality and size of flocs would be to document the settling column visually either by setting up a still-frame camera that can take snapshots of the settling column periodically, or setting up a video recorder to record the experiments during the loading and settling states. A better method may be to contact the manufacturers and inquire about the possibility of bypassing the onboard data averager and just record the data directly from the optical sensor and into our datalog. The plot of the level of mixing (G¿) with respect to the flowrate for the three different flocculator lengths is shown in Figure 11.

Wiki Markup
{cloak}

Wiki Markup
{toggle-cloak:id=Discussion}
Discussion

Wiki Markup
{cloak:id=Discussion}

The data obtained from the this experiment showed the expected characteristics, but more analysis must be performed. Although the results were not very conclusive, it seems as though the team is progressing in the right direction. If a mathematical model was developed to enhance the data analysis, the experimental data could become even more useful. While the experimental setup still has some flaws---especially with respect to clay sedimentation and keeping effluent turbidities constant, the setup proved to be robust and capable of gathering data that accurately represents what is happening in the flocculator at the operating parameters tested. There are also some doubts about the accuracy with which the effluent turbidimeter measures a sample with large suspended flocs. Since the flocs move in and out of the path of the light, fluctuations affect the way the turbidimeter averages and displays the turbidity. Perhaps multiple successive runs of the exact same experiment can be done to determine whether averaging multiple runs can help refine the data.

Wiki Markup
{cloak}

Back to Tube Floc Research