Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Parameter

Value

Energy Dissipation Rate

30 mW/kg

Collision Potential

100 m^2/3

Reynolds Number

4000

Hydraulic Residence Time

7.5 min

Inner Diameter of Tubing

3.18 cm

Length of Flocculator

56.35 m

Number of Coils

30

Diameter of Coil

0.614 m

Unconstricted Height

1.125 m

Constricted Height

1.464 m

The Fall 2013 team worked on the construction of the flocculator according to the design parameters listed above. The Spring and Fall 2014 teams worked on preparing the apparatus for experimentation by introducing a settled water turbidity unit and updating the process controller method file. The team will perform experiments controlling temperature, pressure, influent turbidity and measure effluent turbidity, floc size distribtuion and pC*. 

Section
Column
Members

Felice Chan
MingZe Niu
William Pennock

Email Team

Column
Documents

 

Challenges

Tasks

Symposium

Final Presentation

Final Report

Spring '15Image Added     
Fall '14Image Added Image Added Image AddedImage AddedImage Added 

Summer '14

 

 

 

 

 

Spring '14

Fall '13

Summer '13

Column
 

...