Example of Graphs

Figure 1 and 2 are graphs from the experimental set up setup with an influent turbidity around 100 NTU, flocculator length of 2796 cm, flow rate of 5 mL/s, and an alum dosage ranging from 20 to 55 mg/L. Figure 1 represents the residual turbidity graph plotting the resulting turbidity from flocs with velocities lower than 0.12 mm/s. Figure 2 is the fitted gamma PDF graph showing the probability distribution of particle population with respect to Vs. See here (See experiment conducted on October 20, 2009 for more details on this experiment.)


FIGURE 1: The graph plots the residual turbidity vs. sedimentation velocity for each Alum dose ranging 20 mg/L~55 mg/L


FIGURE 2: The graph plots normalized turbidity vs. sedimentation velocity for each Alum dose ranging 20 mg/L~55 mg/L