| 3D Convection through an Electronics Box - Panel |
---|
|
...
| 3D Convection through an Electronics Box - Panel |
---|
|
Physics Setup
Update Project
...
Input the speed into the Velocity Magnitude. Please note that the units for the Velocity Magnitude should be in/s and not m/s as in the picture.
![](/download/attachments/167412987/InletBC.png?version=1&modificationDate=1326234375000&api=v2)
Next, click on the Thermal Tab. We need to input the temperature of the incoming air. The ambient air is 114 degrees Fahrenheit. FLUENT only accepts temperatures in Kelvin. 114 degrees Fahrenheit = 318.706 Kelvin. Input the ambient temperature, and press OK
...
Now that we are done defining the boundary conditions, we need to specify reference values. In the Outline, select Reference Values. Underneath Compute From, select Inlet.
Go to Step 5: Numerical Solution