Verification & Validation
You need to carry out the following verification studies on the case with no plaque and the case with plaque configuration #1 and no blood clot.
- Check that the boundary conditions have been applied correctly.
- Check that the mesh is fine enough by performing a refinement study. Consider at least one refined mesh in addition to the original mesh.
- Check that the iterations have converged. You can do this by monitoring the residuals and also another parameter such as total resistance on the walls.
- Check that mass and momentum are conserved in the flow domain.