After eliminating both bucket theories, we decided that testing the last two designs in a lab would not be difficult and would give more realistic, tangible results than our calculations. (You need to put this as a separate page and list separate experiments on different pages)

We used the pilot plant to test our retrofit design in an environment that replicated the actual plants as closely as possible. We set the flow rate of the pilot plant at about 150L/min, which, coupled with the 7.5cm-diameter LFOM, would be roughly comparable to the 400L/min, 15cm diameter LFOM in the plant at Cuatro Comunidades. (You need to compare it to the sizes in AguaClara plants as well as parameters in AguaClara plants)

The first design we tested was the vertical/inclined plane. We used a 5cm-wide, 60cm-long steel plate to test the effectiveness of this plan to reduce water aeration. We were looking at the amount of bubbles formed under the LFOM to determine results, and documented them photographically.

Next, we used various-sized pipes inserted within the LFOM to test the "pipe within the LFOM" theory. First, we tested a 3cm-diameter pipe by inserting it vertically into the 7.5cm-inner diameter LFOM. Second, we tested a 5cm pipe, and noticed that it produced a reduction of bubbles. After leaving the 5cm pipe in the LFOM for 5 minutes to ensure no overflow, we moved to test the 6cm pipe. This pipe also showed signs of reducing the amount of bubbles, so we left it in for 5 minutes as well to determine if it would overflow, which it eventually did.

Results and Discussion

Vertical/Incline Planes

Unfortunately, we determined visually that there was very little, if any, change in the amount of bubbles formed before and after inserting the steel plate into the LFOM. Even at various angles of inclination, the amount of bubbles formed was the same. We believe it was ineffective for two reasons. First, the spread of orifices wraps around the pipe far enough that the jets of water at the edge do not touch the steel plate. Second, the water jets are flowing fast enough that the water simply ricochets off the steel plate, instead of running down the plate as intended. See the gallery of photos below for photos illustrating our results.

"Pipe within the LFOM"

With our initial test of the 3cm pipe, there was no noticeable change in the amount of bubbles formed under the LFOM. For the 5cm-diameter pipe we found a drastic reduction in the amount of bubbles formed under the LFOM. Keeping the pipe in for 5 minutes showed no signs of overflowing the LFOM or even raising the water level, so we can assume that 5cm is a possible solution. Finally, we tested a 6cm pipe for 5 minutes in the LFOM. We noticed that the water level outside the LFOM rose slowly throughout the 5 minutes until the water flowed over the top of the LFOM. This clearly meant that the 6cm pipe was too big, and was causing a backup of water within the LFOM. (When explaining these results, how are these helpful to the dimensions in an AguaClara plant at 6". If they are helpful, talk about how you would scale this.)

The Vertical Plane and "Pipe within the LFOM" tests and results can be found at the vertical plane page and the "pipe within a pipe" page.

Results and Discussion

We We were able to document results for each variation of the designs visually with photographs and short movies on cameras, see the gallery below to view the photos.

...

At the end of all of our testing, we determined , we found that inserting a vertical plane into the LFOM would not effectively reduce the bubble formation enough to solve the problem. However, we did determine that inserting a 5cm-diameter pipe would effectively reduce the amount of bubbles produced by the LFOM, while not constricting the overall plant flow rate. This would translate to about a 10cm-diameter pipe in the AguaClara plant at Cuatro Comunidades. Hopefully this design change can be easily executed in the AguaClara plants in Honduras to fix the foam problem. (This only works for a 7.5" I.D. LFOM. You cannot make this conclusion for the AguaClara plant. What about the inclined plane? Does this work??)