Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Migration of unmigrated content due to installation of a new plugin

...

 

Laminar

Turbulent

Linear doser

Latex
Wiki Markup
{latex}$$Q\alpha h$${
}
Latex
Wiki Markup
{latex}$$Q^2 \alpha h$${latex}

Orifice doser

Latex
Wiki Markup
{latex}$$
Q\alpha \sqrt h 
$${latex}
Wiki Markup
Latex
{latex}$$
Q\alpha \sqrt h 
$${latex}

where:

Wiki Markup
Latex
{latex}$$\alpha $${latex}
= proportional to

The connection between the flow control and the flow measurement aspect of the dosing mechanism is important to understand the evolution of dosing mechanisms in AguaClara plants.
Since the nonlinear chemical doser has the same relationship between flow and head at the turbulent ranges; AguaClara plants can be scaled up to much higher flow rates without being limited by the turbulence in the dosing tube. This is a huge advantage of the nonlinear system because it expands the AguaClara plants capabilities to serve much larger communities. The size of AguaClara plants is no longer limited to the flow limitations in the dosing tube.

As mentioned, the nonlinear doser uses the minor losses caused by the orifice instead of a dosing tube (major losses) to control the relationship between changing plant flow rates and chemical dose. The flow rate through the Chemical Dose Controller (CDC) is related to the available head by the equation:

Latex
Wiki Markup
{latex}$$Q_{Cdc}  = K_{orifice}\sqrt {2gh_{Cdc} } $${latex}

where

  • Latex
    Wiki Markup
    {latex}$$Q_{Cdc} $${latex}
    is the chemical flow rate
  • Latex
    Wiki Markup
    {latex}$$ K_{orifice} $${latex}
    is the orifice coefficient
  • h is the available head

The desired chemical dose to the plant can be determined by a mass balance:

Latex
Wiki Markup
{latex}$$C_p  = {{C_c Q_{Cdc} } \over {Q_{Plant} }}$${latex}

where

  • C c is the chemical stock concentration
  • C p is the chemical dose

The influent raw water leaves the entrance tank through the Rapid Mix Tube which is the entry point for the dosing of alum. In the Rapid mix tube, an orifice is located in the tube to generate macro and micro-scale mixing. The entry point for the dosing of alum with the raw water has been redesigned to be submerged in the entrance tank in order to possibly reduce the occurrence of foam in the flocculator. After conversations with Dan Smith, the AguaClara engineer in Honduras, there doesn't appear to be foam forming in the Agalteca plant, where this dosing system has been implemented.
The flow of water through an AguaClara plant can be modeled as minor losses due to flow expansions. The relationship between plant flow rate and head loss through the plant is governed by the minor loss equation shown below.

Latex
Wiki Markup
{latex}$$ h{}_{plant} = K_{plant} {{Q_{plant} ^2 } \over {2g}}$${latex}

where:

Latex
Wiki Markup
{latex}$$ K_{plant} $${latex}
= plant minor loss coefficient

The equation above is important since it defines the relationship between plant flow and head loss through the plant, which is important as well for our dosing apparatus. The CDC uses a lever arm with a float and counterweight to relate the dosing to the changes in the entrance tank water level, which is a function of the influent flow rate. An increase in head loss links the chemical flow rate to the plant flow rate and the chemical dose (mg/L) will be constant as plant flow varies.As can be seen above, the equation which describes the flow of water through plant and the orifice equation which relates flow of alum in the dosing system both have the same relationship between flow rate and head loss. Since the flow rate for both the plant and alum flow are each related by the square root of the head loss, the two flows can be linked through the float in the entrance tank. Any rise
For a detailed step by step description of the steps involved with measuring the plant flow rate please see flow measurement section of the Chemical Dose Controller Manual.
The dosing tube must be designed to minimize major losses so that minor losses dominate head loss. The amount of major losses due to the friction in the dosing tube will vary based on the flow of alum going through the dosing tube, with higher head loss occurring at higher alum flow rates. As a result, it is not desirable to set the size of the orifice based on the varying major losses through the dosing tube, so the head loss caused by the orifice needs far outweigh major losses so the friction in the tube can be ignored. As a result, the dosing tube needs to have a large enough diameter so that the effects of major losses are not significant when compared to the minor losses causes by the orifice. The graph below illustrates the relative contributions of head loss caused by a large 2 mm orifice cap as opposed to the major losses through the dosing tube.

{center:class=myclass}{center}
Center
classmyclass
Wiki Markup

Figure 1: Major loss contribution to the total head loss

...