We'll use an initial guess that is constant over the entire flow domain and equal to the values at the inlet:

Solution > Solution Initialization > Standard Initialization



In the Solution Initialization menu that comes up, choose inlet under Compute From. The Axial Velocity for all cells will be set to 1 m/s, the Radial Velocity to 0 m/s and the Gauge Pressure to 0 Pa. The Turbulence Kinetic Energy and Dissipation Rate(scroll down to see it) values are set from the prescribed values for the Turbulence Intensity and Hydraulic Diameter at the inlet.

...

Solve for 700 iterations.

 Solution > Run Calculation

In the Iterate menu that comes up, change the Number of Iterations to 700. Click Calculate.

...

In addition to the standard data quantities, we would also like to view the results for the Skin Friction Coefficient. This quantity is not transferred to the post-processor by default; so we have to do it manually.

File > Data File Quantities

Under Additional Quantities, select Skin Friction Coefficient, which should be roughly half way down. Your window should now look like this:

...