Summer

...

2009

...

CDC

...

Research

Overview

Abstract

In some AguaClara plants, a surface foam develops at the end of rapid mix. The initial focus of the research was on the chemical conditions required for this surface foam to develop then the focus shifted to the fluid mechanics that make this occurrence possible and the simple retrofit designs that can ameliorate these conditions. In the initial experiments, different chemical conditions were tested for using a series of jar mixers and one-gallon tanks that modeled rapid mix. The first few trials tests ran a constant supply of clay with varying amounts of alum but these did not exhibit any form of surface foam formation. Subsequent trials included organic matter: humic acid, but these only produced large non persistent bubbles. It was not until a stronger surfactant, liquid soap, was added to the baffle spacing that a surface foam with strong persistent bubbles developed. From these experiments it was concluded that air entrainment along with a surfactant in the raw water are the main chemical factors behind surface foam formation.

Upon observing that waterfalls, like the one found in the LFOM, created the ideal fluid dynamic conditions for air entrainment; the second half of the research focused on retrofitting the LFOM at current AguaClara plants. The four designs that were suggested either used a submerged orifice, a vertical surface area or an inclined plane to decrease the velocity of the incoming water through the LFOM. In testing the viability of each design option the three limiting parameters of foam formation from water jets were recognized and documented.

Introduction and Objectives

For the summer of 2009, our team has three main goals:

  • Attempt to recreate the foam in a laboratory setting that has been forming in many of the AguaClara plants in Hoduras.
  • Design a way to retrofit the current plants to eliminate the foam
  • Learn about the current design for a Nonlinear Chemical Dose Controller and then update MathCAD code for the controller and hopefully be able to build a fully functional prototype by the end of the summer.

These goals are very important to the overall goals of AguaClara for a number of reasons. The foam that forms in the current AguaClara plants both increases the amount of work that plant operators have to spend to keep the water clean, and reduces the overall effectiveness of the plants. Although the foam cannot flow very far in the plant itself, it can be blown around by wind to the surface of the sedimentation tank. Small bubbles formed by decreased surface tension in rapid mix could persist as far as the sedimentation tank, where they would come out, possibly causing the floating floc problem. We suspect that the surfactants and natural organic matter lower the surface tension energy requirements, possibly creating these small bubbles that stay in solution long enough to reach the sedimentation tank.

As AguaClara continues to grow and serve larger communities, we will be building plants with larger capacities, where the amount of foam produced from our conventional LFOM design would be impossible to clean. Currently, the plant operators simply scoop the foam off the surface of the water with buckets - not the most sanitary or effective solution. Therefore, it is imperative that we find a solution not only for the current plants in operation, but also for the future plants we design. This summer we learned how the foam is created, and now we are exploring design changes we can make that will reduce or even eliminate foam formation.

Also, as we evolve to build larger plants, the Linear Chemical Dose Controller (LCDC) won't be able to provide a sufficient dose of chemicals to treat the larger flow rates. The CDC team from past semesters has found that the LCDC can only provide chemical flows up to 400mL/min, which is too low for larger plants. Linear dose control depends on a change in head in the plant inflow tank to move a float up and down, which changes the flow of alum into the water. Thus, a Nonlinear Chemical Dose Controller (NCDC), where flow will not vary linearly with water height like the LCDC, is needed for bigger plants. A discussion of the need for a NCDC can be found in the second paragraph on the NCDC page. This summer we will need to improve upon the initial design of a NCDC in order to make it more dependable and robust.

It is our hope that at the end of the summer, the plant operators in Honduras will have a quick-fix way to eliminate the foam forming in their plants, and that future AguaClara plants will have larger capacities, allowing them to provide clean, foam free drinking water for more and more people.

Summer 2009 CDC Research Team's goals and meeting minutes.

Current Research

Determining the Cause of Surface Foam Experiments

Retrofitting Plants to Prevent Aeration Experiments