Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Migrated to Confluence 4.0

Step 2: Specify element type and constants

Enter the Preprocessor module

Main Menu > Preprocessor

This is the module where you create the geometry, specify appropriate displacement constraints and loading, and mesh the geometry. We are more or less going to march down this menu to set up the problem. You will find yourself negotiating through a series of menus as you work off the Main Menu.

Specify Element Type

Main Menu > Preprocessor> Element Type > Add/Edit/Delete > Add...

Pick Structural Link in the left field and 2D spar 1 in the right field. Click OK to select this element.


 

Now you will see the following in the Element Types dialog box:

 
LINK1 appears as the only defined element type in the Element Types dialog box. To view the help pages for this element type, click on Help in the Element Types dialog box. This brings up the Help window. Click on Search in the left pane and type in LINK1. (If the left pane is hidden, click the Show button in the toolbar) The first search result is the help page for the LINK1 element. Note that this is a two-dimensional spar element that supports uniaxial tension and compression but not bending, so it is appropriate for modeling a truss structure. There are two degrees of freedom at each of its two nodes: translations in the nodal x and y directions. The "1" in the element name is the internal reference number for this element type in ANSYS' list of available element types.

...

Close the Element Types window by clicking Close.

Specify Element Constants

Main Menu > Preprocessor > Real Constants > Add/ Edit/ Delete

...

We now enter the constants needed for the LINK1 element. For AREA, enter 0.01 which is the cross-sectional area of the element. We'll work in SI units. Leave the Initial strain field blank since it's not applicable to our problem.

 
It is the responsibility of the ANSYS user to make sure that the values entered are in consistent units. Click OK.

We see in the Real Constants menu that the constant set that we just created is "Set 1". So, when we mesh the geometry later on, we'll use the reference no. 1 to assign this constant set.


 
Click Close in the Real Constants dialog box.Go to Step 3: Specify material properties