The goals of this team are to refine the design of the constant head tank, work with the design team to create labels and scales for the various components, and work with AguaClara LLC to determine if the dose controller will be packaged and sold by AguaClara LLC or built in country.


Section
h6. Chemical Dose Controller (CDC
Linear Chemical Dose Controller (LCDC/LFOM)
Column
Wiki Markup
Excerpt

The

linear Chemical

Dose

Controller

(LCDC) is

a

critical

piece

of

the

AguaClara

technology

which

couples

the

plant

flow

rate

with

the

flow

rate

of

the

coagulant

or

disinfectant

stock

solution.

The

result

is

a

semi-automated

system

in

which

the

plant

operator

only

needs

to

set

a

dose

for

the

chemical

and

it

will

be

administered

automatically

as

the

plant

flow

rate

varies.

The

system

has

evolved

steadily

with

major

advances

every

year.

The

ability

to

accurately

and

predictably

control

the

alum

and

chlorine

dosages

without

electricity

sets

AguaClara

apart

from

other

water

treatment

technologies.

{float:left|border=none} h6. Team Members [Chris Guerrero|cmg227] [Drew Hart|abh35] [Matthew Higgins|mjh97] [Akta Patel|app37] [Adam Salwen|abs265] {float} {float:left|border=none} h6. Chemical Dose Controller Documents | | Challenges | Tasks | Teach-In | Presentation | Final Report | | Summer '11 | [!Research^word_icon.jpeg|height=25!|^CDCLFOMChallenges.doc] | | | | | | Spring '11 | [!Research^word_icon.jpeg|height=25!|^CDCLFOMChallengesSpring2011.doc] |[!Research^word_icon.jpeg|height=25!|^CDCLFOMTasksSpring2011.doc] | [!Research^ppt_icon.jpg|height=25!|^CDCLFOMTeachinSpring2011.ppt] |[!Research^ppt_icon.jpg|height=25!|^CDCLFOMPresentationSpring2011.ppt] | [!Research^word_icon.jpeg|height=25!|^CDCLFOMFinalReportSpring2011.doc] | {float}

Fall 2016: This semester the CDC team redesigned the CHTs so that all four tanks are connected to each other, and so that the calibration columns are attached to the CHT module. Additionally, the team recreated and modified the modular CDC system designed in past semesters to address the goals of being fully chemical resistant, compact, and simple in operation and maintenance. The new CHT will be demonstrated and eventually implemented in Honduras.

 

The chemical dose controller consists of four total stock tanks, two calibration columns, and four constant head tanks. There are two stock tanks for chlorine and two stock tanks for polyaluminum chloride. If one tank for a particular chemical runs out, the second stock tank serves as a backup. The two chlorine stock tanks have individual outlet tubing but this tubing joins together into one tube. At this point, there is a diverted pipe that leads an upright rigid clear PVC pipe which serves as our calibration column. There is one calibration column each for chlorine and for polyaluminum chloride.

The calibration columns serve to measure the dosage of the chemicals being added to the treated water. The calibration columns function by first closing the valve to the CHT and then opening the valve to the calibration column from the stock tank. The plant operator allows the calibration column to fill, closes the valve to the stock tank, then opens the valve to the CHT. The operator then measures how much much time it takes for a predetermined amount of chemical to drop and based off this, determines the dosing rate.

The design of the second and final iteration for the semester maintained the same basic structure as the first iteration of Fall 2016, save for the alterations in plumbing orientation. In the second iteration, the tanks were extended in the direction of the float valves, so that the plumbing can be vertically oriented in the back of the CHT and attached to the wall as opposed to being horizontally oriented through the back of the CHT.

 

Image Added


Image Added

Section
Column
width170px
LCDC Video

http://www.youtube.com/watch?v=nA824OvTNrs&feature=youtu.be

Team Members

Anna Doyle

Cynthia Chan

Annie Cashon

Susan McGrattan

Karan Newatia

Email Team

Section
Column
Documents
Section
2008 CDC
2009 Rapid Mix

Column
See also:

2011 High Flow Dose Controller
2009 Rapid Mix
2008 Linear Chemical Dose Controller

Column

Image Removed

Image Removed

Panel
titleRelated Research
borderStylenone