Verification & Validation

 

  1. Perform additional runs with timesteps of 0.02 and 1s. Comment on the stability of the scheme relating to the timestep by comparing the residuals. 
  2. Compare the residuals and the vorticity figures for a mesh of 128x64 or another mesh of your choosing. Is there any noticeable differences between the results using different mesh sizes?  

Effect of Uniform Initial Condition

In our simulation, we patched the cells behind the cylinder to have a starting velocity of .2 m/s so that we would get the vortex shedding earlier. This also allowed us to better see the oscilliation of the lift coefficient as flow time increased. 

Image Added

Above, we see the variation of the lift coefficient with the flow time if we had not patched the region. 

Image Added

Above, we see the variation of the lift coefficient with the folw time with the region patch. This patch was using .5 < x < 32 and 0 < y < 32. Note how we see the shedding more quickly than if we had not patched the region. 

 

Effect of Timestep on Solution

In order to effectively capture the vortex shedding, a small enough timestep was needed. It was recommeded to have roughly 20 - 25 timesteps per cycle hence we used a timestep of .2. The resulting plot in the numerical results showing how the lift coefficient oscillated due to the vortex shedding is shown below. To compare the effect of the timestep size, we continue to plot the lift coefficient after the oscillations have been established with a timestep of .02 seconds. Changing the timestep changes the resolution, so with a smaller timestep we expect a better resolution when seeing the oscillation of the lift coefficient. 

Image Added

Timestep = .2 s

Image Added

Timestep = .2 -> .02s

You can notice here how the shedding is captured much more effectively using a timestep of .02. 

 

We also run the simulation with a timestep of 1s. Notice how we see a smooth curve for the lift coefficient, rather than the oscillations due to the vortex shedding.

Image Added

Timestep = 1s

Strouhal Number Comparison

The Strouhal Number from the literature is reported to be .183. It is expected that the Strouhal Number will be roughly .2 for flow past the cylinder. By plotting for 600 more time steps, we obtain the Cl vs. Flow time graph below and see how the shedding has become constant. We can do a rough estimate of the frequency by taking an amount of time and seeing how many peaks occur in that time. Using this frequency, we can calculate the Strouhal Number for our simulation. 

Image Added

We see about 10 peaks in 60 seconds, giving a frequency of .1667 which is close to the literature and around what we would expect. 

 Go to Exercises
Go to all FLUENT Learning Modules

...

Author: John Singleton and Rajesh Bhaskaran

...