We ask FLUENT to solve the axisymmetric form of the governing equations. When you do this, the solver switches to cylindrical polar coordinates. So from here on, you should interpret the horizontal coordinate as axial and the vertical coordinate as radial.
General > Solver > 2D Space > Axisymmetric

 
The energy equation is turned off by default. Turn on the energy equation. Note that in most cases, you'll have to double-click on an item to select it. 
Models > Energy - Off > Edit...
Turn on the Energy Equation and click OK.
 
By default, FLUENT will assume the flow is laminar. Let's tell it that our flow is turbulent rather than laminar and that we want to use the k-epsilon turbulence model to simulate our turbulent flow. This means FLUENT will solve for mean (i.e. Reynolds-averaged) quantities at every point in the domainvalues of velocity, pressure and temperature. It will add the k and epsilon equations to the governing equations to calculate the effect of the turbulent fluctuations on the mean, as discussed in the Pre-Analysis step.

...