Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Since this problem statement only specified the lid of the box as moving, we assign a wall condition to the top face of the volume. Select the Physics task.  In the Fluid Flow Conditions section, press Add > Wall and select the top face of the flow volume. In the Flow Specification, change Wall velocity from Stationary to Moving and specify the Magnitude as 1 [m s^-1], as given in the problem description. Now that the wall is moving, a direction must be specified by inputting a value in the Cartesian Direction Components. Input 1 as X while Y and Z must be zero. See below for an example.

Image Modified

A symmetry condition is applied to two opposing faces (shown below). Select symmetry from the Add dropdown menu and apply it to two opposing faces. 

Image Modified

Next, a wall condition must be added to all surfaces that are not already defined. Wall can be found in the same Add menu as the previous conditions. Once the Wall condition is chosen, AIM selects every face that doesn't already have a boundary condition on it.

Image Modified

 

 
Go to Step 5: Results

...