Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

The temperatures for both sides can be input as Solid Thermal Conditions. Follow the highlighted blue Next Step button to add these temperatures via Add > Solid Thermal Conditions > Temperature. Another way of adding temperature is to press the Physics button in the workflow and press Solid Thermal Conditions > Add > Temperature. Select the appropriate faces and assign them the respective temperatures. Once you have selected a face, in order to assign it a temperature you must press the blue + button and then input the correlating temperature. The room temperature surface was said to be 80 degrees Fahrenheit and the heated surface was said to be 400 degrees Fahrenheit. Below is an example of what the bar will look like with the temperature conditions defined.

Image Modified

Press Physics in the workflow below to return to the main Physics display and press Solver Options > Output Controls 1 > Output type > All.  Do this for both Output Specification 1 and Output Specification 2.

...