In the Outline window, click Monitors to open the Monitors window. In the Monitors window, select Residuals - Print,Plot and press Edit.... This will open the Residual Monitors window. We want to change the convergence criteria for our solution. Under Equation and to the right of Continuity, change the Absolute Criteria to 1e-6. Repeat for x-velocity, y-velocity, and energy, then press OK.


Reference Values

In the Outline window, select Reference Values. Under Compute From, select Inlet. Ensure that the values displayed are the values we specified. We are now ready to setup the solution.

Solution Initialization

In the Outline window, select Solution Initialization. We need to make an "Initial Guess" to the solution so FLUENT can iterate to find the final solution. In the Solution Initialization window, select Standard Initialization then under Compute from, select Inlet from the drop down box. Check to see that the values that generate match our inputted values, then press Initialize

...