Initialize the solution by going to Solution-Solution Initialization and using Inlet 1 with axial velocity 1m/s to initialize the domain. Check your initialization by going to Results-Graphics and Animations, and displaying selecting "Contours" under the Graphics section, and clicking the "Set Up" button. Display the stream function (constant values along streamlines, which are tangent to flow velocity)  for the fluid surface as shown in the dialogue box below. Click the Display button.

...