Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Sampling Method

Overview

Raw water running through flocculation tank can be sampled at any desired location. Sampling lines run to turbidimeters from three mobile tube settlers. The tube settlers mimic sedimentation. Additionally a sampling line runs from the raw water inlet to a turbidimeter. Turbidity data is stored in a excel spreadsheet using process controller.

Tube settlers

Tube settlers are used to test effluent turbidity at different locations. The tube settlers were designed to mimic the sedimentation tank that would traditionally follow the flocculator. Tube settlers were chosen because they provide an inexpensive way to sample and create a minimal disturbance within in the tank. Using this method, different locations of the tank can be sampled. Data gathered can be used to assess how each stage of the tank is affecting the final effluent turbidity. The three glass tube settlers used were of 60 cm length and 2.5 cm diameter. A peristaltic pump was used to transport the water to the three turbidimeters.

...

Dimensions and Variables chosen: -

  • b = diameter = 2.5 cm

...

  • L = length of the tube settler = 60 cm

...

  • alpha = optimum angle = 60°

...

LaTeX Markup:

\large
$$
V_\alpha = V_c \left( {{L \over b}\cos \alpha + \sin \alpha } \right)
$$|sedimentation - upflow velocity">

Include Page
AGUACLARA:sedimentation - upflow velocity
AGUACLARA:sedimentation - upflow velocity

<div class=<div class=

The following equations were adopted from Shultz and Okun for determining critical velocity for up flow through a tube. The flow rate calculated for our initial configuration was 44 mL/min. There is a linear relationship between pump speed and the flow rate through the settling tube. The flow rate though the settling tube also has a linear relationship to the critical velocity of the sedimentation process in the tube. It is important to note that the critical velocity of the settling tubes is the same as the critical velocity that can be found in the sedimentation tanks at Ojojona.
The setup of the tube settlers in the tank was the next design step. Originally the tube settlers were to be hung from the edge of the tanks at designated locations. On further inspection however, when laid between the baffles on top of the connectors they are at the correct angle and so can easily be relocated and do not require any attachment to the tank.
The final design consists of the tube settlers nestled between the baffles, and then connected to the peristaltic pump. The peristaltic pump pulls water from the peristaltic pump at the correct velocity and the water is routed through a turbidimeter in order to measure the turbidity. Also installed is a turbidimeter that measures the influent turbidity of the water before it reaches the tank. The turbidimeter is gravity fed.

...