Method | Gtheta Value for k-e realizable 1_5 W one baffle |
---|---|
Ave of Cell's Product (1) | .6698 |
Ave G* Floc residence time (2) | 45 |
Ave G*Ave N (3) | .617 |
Gtheta was also plotted using the custom function in FLUENT. Wiki Markup
Wiki Markup |
---|
\\ !GthetaaGtheta plot.png|width=713,height=412! GӨ = \[ε/υ\]^1/2^ \* \[Cell Volume/Vol. flow rate{~}cell~/Cell Volume\] (4) \\ \\ The Gtheta plot values range from 0 to 3000, and the highest values are concentrated at the separation regime. \\ |
Conclusion
The Gtheta that compares best to mechanically mixed floculators is the Gtheta calculated from method 2, where the G value is averaged, and this averaged value is multiplied by the residence time of a particle. As suggested in discussions with Monroe, this simplistic definition fails to incorporate the weighted flow average.
...