In the Solution Initialization menu that comes up, choose inlet under Compute From. The Axial Velocity for all cells will be set to 1 m/s, the Radial Velocity to 0 m/s and the Gauge Pressure to 0 Pa. The Turbulence Kinetic Energy and Dissipation Rate (scroll down to see it) values are set from the prescribed values for the Turbulence Intensity and Hydraulic Diameter at the inlet.
Image Added
 
Click Init. Close the Solution Initialization window.

Set Convergence Criteria

Recall that FLUENT reports a residual for each governing equation being solved. The residual is a measure of how well the current solution satisfies the discrete form of each governing equation. We'll iterate the solution until the residual for each equation falls below 1e-6.

...

Notice that Convergence Criterion has to be set for the k and epsilon equations in addition to the three equations in the last tutorial. Set the Convergence Criterion to be 1e-06 for all five equations being solved.

Select Print and Plot under Options. This will print as well plot the residuals as they are calculated which you will use to monitor convergence.

...