Linear Chemical Dose Controller
Abstract
The original Chemical Dose Controller (CDC) is designed to have a linear relationship between the flow of alum and the height of water in the entrance tank. The CDC itself is a combination of three previous subteams: the Linear Flow Orifice Meter; the Linear Chemical Doser; and the Flow Controller. These three devices work together to automatically change the amount of alum that enters rapid mix as the flow through the plant is increased. A description of these devices, and how they work can be found below. Since the linear CDC is currently in use in Honduras, the current goal for this project is to make the design more robust.
Current Research
Wiki Markup |
---|
{float:right|border=2px solid black|width=250px} [!Laboratory Research Set-ups^ACDF08 Labeled Context View.jpg|width=250px!|Laboratory Research Set-ups] {float} |
The vertical chemical dosing tube portion of the CDC was tested with various tubing diameters to determine the failure point. If free fall or open channel flow was observed within the vertical drop tubing, then the dosing would be accurate. We determined that the smallest allowable inner tubing diameter is one quarter inch.
Currently, a preliminary manuscript based on the development and research of the Linear Chemical Dose Controller is being written for publication as a journal article. All drafts of the scientific research paper are attached to this page for viewing and editing by all AguaClara team members. Considerable editing and revising is required for the paper. The research that has been conducted in previous semesters will need to reconciled and verified. In addition, much of the data may not be publishable. Many experiments will need to be redone or performed for the purpose of the paper.
Relevant Data Files
LFOM Failure Experiment
LFOM weir design documentation
Previous Research
Linear Flow Orifice Meter (LFOM)
The Linear Flow Orifice Meter riser pipe, LFOM, is located in the entrance tank. It is used in the plant when chemical dose flows are laminar. The LFOM tank creates a linear relationship between the flow rate through the plant and the height of water in the entrance tank so that a float system can be used control the chemical dose.
Linear Chemical Doser
The Linear Chemical Doser creates a directly proportional relationship between the plant inflow tank water level and the flow controller outflow tubing level.
Flow Controller
The Flow Controller maintains a constant head level in a small bottle so that hydraulics can be used to dose a specific chemical flow rate solely by controlling the outflow tubing level.