Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Image Added

  1. MAKE SURE NO ONE IS USING THE SYSTEM BEFORE YOU BEGIN.
  2. In Sensor Configuration set height of sensor to 0 cm by typing in “0” in the box and selecting Set (see image). 
  3. Run system in “Run Run Activated Carbon and Tap Water” Water ("Run AC and Tap") until water goes into the overflow pipe (the only PVC pipe that runs down from the tank).  You can hear water in the overflow by putting your ear to the pipe. 
  4. Turn to “OFF” state
  5. Switch to the Graphs tab and wait for the water level to reach a steady height.
  6. Return to Sensor Configuration and set sensor height to 31.7 8 cm by typing “31.7” 8” in the box and selecting Set
  7. Exit Sensor Configuration and run system.
  8. Repeat for other pressure sensor if needed.