Include Page | ||||
---|---|---|---|---|
|
Include Page | ||||
---|---|---|---|---|
|
Physics Setup
Your workbench project should look like this.
We are done with all the meshing steps but for some reason, a tick mark doesn't appear next to Mesh in the project page. To get the tick mark next to mesh, right-click on it and select Update as shown below.
Launch Fluent
(Double Click) Setup in the Workbench Project Page.
...
Solution Setup > Materials > Fluid > Create/Edit....
Then set the Density to 1 kg/m^3 and set Viscosity to 0.05 kg/m*s. Click Change/Create then click Close.
Boundary Conditions
FarField1
Solution Setup > Boundary Conditions > farfield1.
Set Type to velocity-inlet. Click Edit.... Set Velocity Specification Method to Components, set X-Velocity to 1 m/s, and set Y-Velocity to 0 m/s.
FarField2
Solution Setup > Boundary Conditions > farfield2..
Set Type to pressure-outlet.
Cylinder Wall
Solution Setup > Boundary Conditions > cylinderwall.
Set Type to wall.This is the default.
Reference Values
Solution Setup > Reference Values.
Set the Density to 1 kg/m^3. The other default values will work for the purposes of this simulation.
...